DPDK 22.11.6
|
#include <stdint.h>
#include <rte_compat.h>
#include <rte_common.h>
#include <rte_meter.h>
#include <rte_flow.h>
Go to the source code of this file.
Data Structures | |
struct | rte_mtr_stats |
struct | rte_mtr_meter_profile |
struct | rte_mtr_meter_policy_params |
struct | rte_mtr_params |
struct | rte_mtr_capabilities |
struct | rte_mtr_error |
Macros | |
#define | rte_mtr_policy_pass_color(policy) |
#define | rte_mtr_policy_drop_red(policy) |
Enumerations | |
enum | rte_mtr_stats_type { RTE_MTR_STATS_N_PKTS_GREEN = 1 << 0 , RTE_MTR_STATS_N_PKTS_YELLOW = 1 << 1 , RTE_MTR_STATS_N_PKTS_RED = 1 << 2 , RTE_MTR_STATS_N_PKTS_DROPPED = 1 << 3 , RTE_MTR_STATS_N_BYTES_GREEN = 1 << 4 , RTE_MTR_STATS_N_BYTES_YELLOW = 1 << 5 , RTE_MTR_STATS_N_BYTES_RED = 1 << 6 , RTE_MTR_STATS_N_BYTES_DROPPED = 1 << 7 } |
enum | rte_mtr_algorithm { RTE_MTR_NONE = 0 , RTE_MTR_SRTCM_RFC2697 , RTE_MTR_TRTCM_RFC2698 , RTE_MTR_TRTCM_RFC4115 } |
enum | rte_mtr_color_in_protocol { RTE_MTR_COLOR_IN_PROTO_OUTER_VLAN = RTE_BIT64(0) , RTE_MTR_COLOR_IN_PROTO_INNER_VLAN = RTE_BIT64(1) , RTE_MTR_COLOR_IN_PROTO_OUTER_IP = RTE_BIT64(2) , RTE_MTR_COLOR_IN_PROTO_INNER_IP = RTE_BIT64(3) } |
enum | rte_mtr_error_type { RTE_MTR_ERROR_TYPE_NONE , RTE_MTR_ERROR_TYPE_UNSPECIFIED , RTE_MTR_ERROR_TYPE_METER_PROFILE_ID , RTE_MTR_ERROR_TYPE_METER_PROFILE , RTE_MTR_ERROR_TYPE_METER_PROFILE_PACKET_MODE , RTE_MTR_ERROR_TYPE_MTR_ID , RTE_MTR_ERROR_TYPE_MTR_PARAMS , RTE_MTR_ERROR_TYPE_POLICER_ACTION_GREEN , RTE_MTR_ERROR_TYPE_POLICER_ACTION_YELLOW , RTE_MTR_ERROR_TYPE_POLICER_ACTION_RED , RTE_MTR_ERROR_TYPE_STATS_MASK , RTE_MTR_ERROR_TYPE_STATS , RTE_MTR_ERROR_TYPE_SHARED , RTE_MTR_ERROR_TYPE_METER_POLICY_ID , RTE_MTR_ERROR_TYPE_METER_POLICY } |
Functions | |
__rte_experimental int | rte_mtr_capabilities_get (uint16_t port_id, struct rte_mtr_capabilities *cap, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_profile_add (uint16_t port_id, uint32_t meter_profile_id, struct rte_mtr_meter_profile *profile, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_profile_delete (uint16_t port_id, uint32_t meter_profile_id, struct rte_mtr_error *error) |
__rte_experimental struct rte_flow_meter_profile * | rte_mtr_meter_profile_get (uint16_t port_id, uint32_t meter_profile_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_policy_validate (uint16_t port_id, struct rte_mtr_meter_policy_params *policy, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_policy_add (uint16_t port_id, uint32_t policy_id, struct rte_mtr_meter_policy_params *policy, struct rte_mtr_error *error) |
__rte_experimental struct rte_flow_meter_policy * | rte_mtr_meter_policy_get (uint16_t port_id, uint32_t policy_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_policy_delete (uint16_t port_id, uint32_t policy_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_create (uint16_t port_id, uint32_t mtr_id, struct rte_mtr_params *params, int shared, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_destroy (uint16_t port_id, uint32_t mtr_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_disable (uint16_t port_id, uint32_t mtr_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_enable (uint16_t port_id, uint32_t mtr_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_profile_update (uint16_t port_id, uint32_t mtr_id, uint32_t meter_profile_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_policy_update (uint16_t port_id, uint32_t mtr_id, uint32_t meter_policy_id, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_dscp_table_update (uint16_t port_id, uint32_t mtr_id, enum rte_mtr_color_in_protocol proto, enum rte_color *dscp_table, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_meter_vlan_table_update (uint16_t port_id, uint32_t mtr_id, enum rte_mtr_color_in_protocol proto, enum rte_color *vlan_table, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_color_in_protocol_set (uint16_t port_id, uint32_t mtr_id, enum rte_mtr_color_in_protocol proto, uint32_t priority, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_color_in_protocol_get (uint16_t port_id, uint32_t mtr_id, uint64_t *proto_mask, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_color_in_protocol_priority_get (uint16_t port_id, uint32_t mtr_id, enum rte_mtr_color_in_protocol proto, uint32_t *priority, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_stats_update (uint16_t port_id, uint32_t mtr_id, uint64_t stats_mask, struct rte_mtr_error *error) |
__rte_experimental int | rte_mtr_stats_read (uint16_t port_id, uint32_t mtr_id, struct rte_mtr_stats *stats, uint64_t *stats_mask, int clear, struct rte_mtr_error *error) |
RTE Generic Traffic Metering and Policing API
This interface provides the ability to configure the traffic metering and policing (MTR) in a generic way.
The processing done for each input packet hitting a MTR object is: A) Traffic metering: The packet is assigned a color (the meter output color), based on the previous history of the flow reflected in the current state of the MTR object, according to the specific traffic metering algorithm. The traffic metering algorithm can typically work in color aware mode, in which case the input packet already has an initial color (the input color), or in color blind mode, which is equivalent to considering all input packets initially colored as green. B) Policing: There is a separate policer action configured for each meter output color, which can: a) Drop the packet. b) Keep the same packet color: the policer output color matches the meter output color (essentially a no-op action). c) Recolor the packet: the policer output color is different than the meter output color. The policer output color is the output color of the packet, which is set in the packet meta-data (i.e. struct rte_mbuf::sched::color). C) Statistics: The set of counters maintained for each MTR object is configurable and subject to the implementation support. This set includes the number of packets and bytes dropped or passed for each output color.
Once successfully created, an MTR object is linked to one or several flows through the meter action of the flow API. A) Whether an MTR object is private to a flow or potentially shared by several flows has to be specified at creation time. B) Several meter actions can be potentially registered for the same flow.
Definition in file rte_mtr.h.
#define rte_mtr_policy_pass_color | ( | policy | ) |
#define rte_mtr_policy_drop_red | ( | policy | ) |
Define meter policy action list: GREEN - Do nothing, YELLOW - Do nothing, RED - DROP
enum rte_mtr_stats_type |
Statistics counter type
enum rte_mtr_algorithm |
Traffic metering algorithms
Enumerator | |
---|---|
RTE_MTR_NONE | No traffic metering performed, the output color is the same as the input color for every input packet. The meter of the MTR object is working in pass-through mode, having same effect as meter disable.
|
RTE_MTR_SRTCM_RFC2697 | Single Rate Three Color Marker (srTCM) - IETF RFC 2697. |
RTE_MTR_TRTCM_RFC2698 | Two Rate Three Color Marker (trTCM) - IETF RFC 2698. |
RTE_MTR_TRTCM_RFC4115 | Two Rate Three Color Marker (trTCM) - IETF RFC 4115. |
Input color protocol method
More than one of the method can be enabled for a given meter. Even if enabled, a method might not be applicable to each input packet, in case the associated protocol header is not present in the packet. The highest priority method that is both enabled for the meter and also applicable for the current input packet wins; if none is both enabled and applicable, the default input color is used.
Enumerator | |
---|---|
RTE_MTR_COLOR_IN_PROTO_OUTER_VLAN | Enable the detection of the packet input color based on the outermost VLAN header fields DEI (1 bit) and PCP (3 bits). These fields are used as index into the VLAN table.
|
RTE_MTR_COLOR_IN_PROTO_INNER_VLAN | Enable the detection of the packet input color based on the innermost VLAN header fields DEI (1 bit) and PCP (3 bits). These fields are used as index into the VLAN table.
|
RTE_MTR_COLOR_IN_PROTO_OUTER_IP | Enable the detection of the packet input color based on the outermost IP DSCP field. These fields are used as index into the DSCP table.
|
RTE_MTR_COLOR_IN_PROTO_INNER_IP | Enable the detection of the packet input color based on the innermost IP DSCP field. These fields are used as index into the DSCP table.
|
enum rte_mtr_error_type |
Verbose error types.
Most of them provide the type of the object referenced by struct rte_mtr_error::cause.
Enumerator | |
---|---|
RTE_MTR_ERROR_TYPE_NONE | No error. |
RTE_MTR_ERROR_TYPE_UNSPECIFIED | Cause unspecified. |
__rte_experimental int rte_mtr_capabilities_get | ( | uint16_t | port_id, |
struct rte_mtr_capabilities * | cap, | ||
struct rte_mtr_error * | error | ||
) |
MTR capabilities get
[in] | port_id | The port identifier of the Ethernet device. |
[out] | cap | MTR capabilities. Needs to be pre-allocated and valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_profile_add | ( | uint16_t | port_id, |
uint32_t | meter_profile_id, | ||
struct rte_mtr_meter_profile * | profile, | ||
struct rte_mtr_error * | error | ||
) |
Meter profile add
Create a new meter profile with ID set to meter_profile_id. The new profile is used to create one or several MTR objects.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | meter_profile_id | ID for the new meter profile. Needs to be unused by any of the existing meter profiles added for the current port. |
[in] | profile | Meter profile parameters. Needs to be pre-allocated and valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_profile_delete | ( | uint16_t | port_id, |
uint32_t | meter_profile_id, | ||
struct rte_mtr_error * | error | ||
) |
Meter profile delete
Delete an existing meter profile. This operation fails when there is currently at least one user (i.e. MTR object) of this profile.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | meter_profile_id | Meter profile ID. Needs to be the valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental struct rte_flow_meter_profile * rte_mtr_meter_profile_get | ( | uint16_t | port_id, |
uint32_t | meter_profile_id, | ||
struct rte_mtr_error * | error | ||
) |
Meter profile object get
Get meter profile object for a given meter profile ID.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | meter_profile_id | Meter profile ID. Needs to be the valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_policy_validate | ( | uint16_t | port_id, |
struct rte_mtr_meter_policy_params * | policy, | ||
struct rte_mtr_error * | error | ||
) |
Check whether a meter policy can be created on a given port.
The meter policy is validated for correctness and whether it could be accepted by the device given sufficient resources. The policy is checked against the current capability information meter_policy_n_max configuration. The policy may also optionally be validated against existing device policy resources. This function has no effect on the target device.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | policy | Associated action list per color. list NULL is legal and means no special action. (list terminated by the END action). |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_policy_add | ( | uint16_t | port_id, |
uint32_t | policy_id, | ||
struct rte_mtr_meter_policy_params * | policy, | ||
struct rte_mtr_error * | error | ||
) |
Meter policy add
Create a new meter policy. The new policy is used to create single or multiple MTR objects. The same policy can be used to create multiple MTR objects.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | policy_id | Policy identifier for the new meter policy. |
[in] | policy | Associated actions per color. list NULL is legal and means no special action. Non-NULL list must be terminated. (list terminated by the END action). |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental struct rte_flow_meter_policy * rte_mtr_meter_policy_get | ( | uint16_t | port_id, |
uint32_t | policy_id, | ||
struct rte_mtr_error * | error | ||
) |
Meter policy object get
Get meter policy object for a given meter policy ID.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | policy_id | Meter policy ID. Needs to be the valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_policy_delete | ( | uint16_t | port_id, |
uint32_t | policy_id, | ||
struct rte_mtr_error * | error | ||
) |
Meter policy delete
Delete an existing meter policy. This operation fails when there is currently at least one user (i.e. MTR object) of this policy.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | policy_id | Policy identifier. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_create | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
struct rte_mtr_params * | params, | ||
int | shared, | ||
struct rte_mtr_error * | error | ||
) |
MTR object create
Create a new MTR object for the current port. This object is run as part of associated flow action for traffic metering and policing.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be unused by any of the existing MTR objects. created for the current port. |
[in] | params | MTR object params. Needs to be pre-allocated and valid. |
[in] | shared | Non-zero when this MTR object can be shared by multiple flows, zero when this MTR object can be used by a single flow. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_destroy | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
struct rte_mtr_error * | error | ||
) |
MTR object destroy
Delete an existing MTR object. This operation fails when there is currently at least one user (i.e. flow) of this MTR object.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. created for the current port. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_disable | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
struct rte_mtr_error * | error | ||
) |
MTR object meter disable
Disable the meter of an existing MTR object. In disabled state, the meter of the current MTR object works in pass-through mode, meaning that for each input packet the meter output color is always the same as the input color. In particular, when the meter of the current MTR object is configured in color blind mode, the input color is always green, so the meter output color is also always green. Note that the policer and the statistics of the current MTR object are working as usual while the meter is disabled. No action is taken and this function returns successfully when the meter of the current MTR object is already disabled.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_enable | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
struct rte_mtr_error * | error | ||
) |
MTR object meter enable
Enable the meter of an existing MTR object. If the MTR object has its meter already enabled, then no action is taken and this function returns successfully.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_profile_update | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
uint32_t | meter_profile_id, | ||
struct rte_mtr_error * | error | ||
) |
MTR object meter profile update
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | meter_profile_id | Meter profile ID for the current MTR object. Needs to be valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_policy_update | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
uint32_t | meter_policy_id, | ||
struct rte_mtr_error * | error | ||
) |
MTR object meter policy update
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | meter_policy_id | Meter policy ID for the current MTR object. Needs to be valid. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_dscp_table_update | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
enum rte_mtr_color_in_protocol | proto, | ||
enum rte_color * | dscp_table, | ||
struct rte_mtr_error * | error | ||
) |
MTR object DSCP table update
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | proto | Input color protocol. |
[in] | dscp_table | When non-NULL: it points to a pre-allocated and pre-populated table with exactly 64 elements providing the input color for each value of the IPv4/IPv6 Differentiated Services Code Point (DSCP) input packet field. When NULL: it is equivalent to setting this parameter to an "all-green" populated table (i.e. table with all the 64 elements set to green color). |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_meter_vlan_table_update | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
enum rte_mtr_color_in_protocol | proto, | ||
enum rte_color * | vlan_table, | ||
struct rte_mtr_error * | error | ||
) |
MTR object VLAN table update
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | proto | Input color protocol. |
[in] | vlan_table | When non-NULL: it points to a pre-allocated and pre-populated table with exactly 16 elements providing the input color for each value of the each value of the DEI(1bit), PCP(3 bits) input packet field. When NULL: it is equivalent to setting this parameter to an "all-green" populated table (i.e. table with all the 16 elements set to green color). |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_color_in_protocol_set | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
enum rte_mtr_color_in_protocol | proto, | ||
uint32_t | priority, | ||
struct rte_mtr_error * | error | ||
) |
Set the input color protocol for a given MTR object
More than one of the method can be enabled for a given meter. Even if enabled, a method might not be applicable to each input packet, in case the associated protocol header is not present in the packet. The highest priority method that is both enabled for the meter and also applicable for the current input packet wins; if none is both enabled and applicable, the default input color is used.
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | proto | Input color protocol. |
[in] | priority | Input color protocol priority. Value zero indicates the highest priority. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_color_in_protocol_get | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
uint64_t * | proto_mask, | ||
struct rte_mtr_error * | error | ||
) |
Get the input color protocol for a given MTR object
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[out] | proto_mask | Selected input color protocols as bit mask. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_color_in_protocol_priority_get | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
enum rte_mtr_color_in_protocol | proto, | ||
uint32_t * | priority, | ||
struct rte_mtr_error * | error | ||
) |
Get the priority associated with input color protocol for a given MTR object
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | proto | Input color protocol. |
[out] | priority | Input color protocol priority associated with proto. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_stats_update | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
uint64_t | stats_mask, | ||
struct rte_mtr_error * | error | ||
) |
MTR object enabled statistics counters update
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[in] | stats_mask | Mask of statistics counter types to be enabled for the current MTR object. Any statistics counter type not included in this set is to be disabled for the current MTR object. |
[out] | error | Error details. Filled in only on error, when not NULL. |
__rte_experimental int rte_mtr_stats_read | ( | uint16_t | port_id, |
uint32_t | mtr_id, | ||
struct rte_mtr_stats * | stats, | ||
uint64_t * | stats_mask, | ||
int | clear, | ||
struct rte_mtr_error * | error | ||
) |
MTR object statistics counters read
[in] | port_id | The port identifier of the Ethernet device. |
[in] | mtr_id | MTR object ID. Needs to be valid. |
[out] | stats | When non-NULL, it contains the current value for the statistics counters enabled for the current MTR object. |
[out] | stats_mask | When non-NULL, it contains the mask of statistics counter types that are currently enabled for this MTR object, indicating which of the counters retrieved with the stats structure are valid. |
[in] | clear | When this parameter has a non-zero value, the statistics counters are cleared (i.e. set to zero) immediately after they have been read, otherwise the statistics counters are left untouched. |
[out] | error | Error details. Filled in only on error, when not NULL. |